Page 7 of 26 Setting Start and End of DST 27. The mode indicator “08” will be flashing, press P5 to switch to mode “09” 28. The mode indicator “09” w
Page 8 of 26 Correct Finger Positioning on the Sensor Place finger flat on the sensor surface Place finger in the center of the sensor surface
Page 9 of 26 b. Administrator numbers will appear Axxx and can be assigned numbers A301-A305 7. When you have completed assigning the user, while th
Page 10 of 26 Set Ink Color Change Time 1. Remove top cover 2. Locate the program switch to the left of the finger print reader. Move the switch to
Page 11 of 26 Using the Time Clock Using the Time Card to Clock In 1. When clocking in P1, P3 or P4 must be selected 2. Insert the time card with t
Page 12 of 26 Using a Badge to Clock Out 1. When clocking out P2, P4 or P5 must be selected 2. Insert the time card with the current week facing y
Page 13 of 26 Miscellaneous Input Voltage DC 18v Input Current 1.5A Anti-static Strength < 15KV Operational Relative Humidity 10 – 60% Operatio
Page 14 of 26 Warning: Batteries may leak, overheat, catch fire or explode if proper safety & handling procedures are not followed: • DO NOT get
Page 15 of 26 Troubleshooting Symptom Possible Problem Solution Clock does not power on Power Outage The power source was not properly connected
Page 16 of 26 Symptom Possible Problem Solution Display is in AM/PM hours but clock prints in 24 Hr format The clock display format and print for
Lithium Battery Caution: The circuit board on this terminal is populated with a lithium battery to protect data or programs stored in the Random Acc
Page 17 of 26 5. Q: Why is the light for the fingerprint reader not working? A: Make sure the fingerprint switch is set to “FP ON”. If this doesn’t
Page 18 of 26 Maintenance Replacing the Ribbon Cassette 1. Open clock cover. Press “P3”
Page 19 of 26 Replacing the Circuit Board Batteries The ATR360 is equipped with (2) CR2032 3v Lithium Coin Cell batteries: one battery
Page 20 of 26 Installing the Operational Battery Pack First unplug the clock. The door to the battery pack compartment is located on the
Page 21 of 26 Cleaning the ATR360 Do not use cleaning products that contain alcohol or other strong chemicals as they could discolor or crack the ter
Page 22 of 26 Appendix Connecting External Signal Devices (Bells & Horns) The connections for an external signal device (bells, horns, buzzers, ch
Page 23 of 26 Wall Mounting Instructions The ATR360 can be placed on a table or desk and it can also be mounted to a wall. A mounting template is in
Page 24 of 26 Supplies, Parts & Accessories Part# Description 01-0230-000 24 Volt Switching Relay Kit 01-0270-000 ATR360
Page 25 of 26 Acroprint® Limited Warranty Should you have any questions concerning your warranty information or supplies, please contact the dealer or
Page 26 of 26 Product Registration Card Model No._______________________ Serial No._____________________ First Name______________
Table of Contents Before You Start!...1 What’s In the Box ...
Page 27 of 26 06-0400-000 Rev. D
Page 1 of 26 Before You Start! What’s In the Box • ATR360 Time Recorder • (2) Clock Cover Keys • 18vDC Switching Power Supply • User Manual • (25)
Page 2 of 26 Time Recorder Mode Settings Mode Setting Values Default Value 01 Year 2000 – 2099 Year of Mfg 02 Date 1-12 Mo, 1-31 Date 01, 01 03
Page 3 of 26 Clock Overview Top View Front View • Battery Status Indicator: A fully charged
Page 4 of 26 Rear View
Page 5 of 26 Initial Setup Setting Year 1. Remove top cover a. Locate buttons at the top of the clock labeled P4, P5 and P6 i. P4 changes values d
Page 6 of 26 Synchronizing the RTC to the System Clock 1. Open clock lid. Press "FP Setup" button 2. Press "down" until the